Hyundai Sonata: Purge Control Solenoid Valve (PCSV) Description and Operation - Engine Control System - Engine Control / Fuel SystemHyundai Sonata: Purge Control Solenoid Valve (PCSV) Description and Operation

Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.

    Injector Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance between the injector terminals 1 and 2. 4. Check that the resistance is within t ...

    Purge Control Solenoid Valve (PCSV) Specifications
    Specification ItemSpecificationCoil Resistance (?)22.0 ~ 26.0 [20°C(68°F)] ...

    See also:

    Oil Pump Repair procedures
    Removal and Installation 1. Remove the timing chain cover. (Refer to Timing System - "Timing Chain Cover") 2. Remove the pump cover (A). Tightening torque : 8.8 ~ 13.7N.m (0.9 ~ 1.4kgf.m, ...

    Fuel Filter Repair procedures
    Replacement 1. Remove the fuel pump. (Refer to Fuel Delivery System - "Fuel Pump") 2. Remove the fixing clip (A), and then disconnect the fuel tube (B). 3. Remove the fuel pressure regul ...

    MTS Antenna. Components and Components Location