Hyundai Sonata: Fuel Pressure Control Valve. Repair procedures
Inspection
| 1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
| 2. |
Disconnect the fuel pressure regulator valve connector.
|
| 3. |
Measure resistance between the fuel pressure regulator valve terminals
1 and 2.
|
| 4. |
Check that the resistance is within the specification.
|
Fuel Pressure Control Valve. Schematic Diagrams
Circuit Diagram
...
Canister Close Valve (CCV). Description and Operation
Description
Canister Close Valve (CCV) is installed on the canister ventilation line.
It seals evaporative emission control system by shutting the canister from the
atmosphere when leakage d ...
See also:
Engine number
2.4 engine
2.0 engine
The engine number is stamped on the engine block as shown in the drawing. ...
Emergency fuel filler lid release
An emergency fuel filler lid release is located in the luggage compartment, on
the left side.
If the fuel filler lid does not open using the remote fuel filler lid release,
you can open it ma ...
Troubleshooting
Troubleshooting
Symptom
Suspect area
Engine will not start or struggle to start
Vapor hose damaged or disconnected