Hyundai Sonata: Fuel Pressure Control Valve. Repair procedures - Engine Control System - Engine Control/Fuel SystemHyundai Sonata: Fuel Pressure Control Valve. Repair procedures

Inspection

1.
Turn the ignition switch OFF and disconnect the battery negative (-) cable.
2.
Disconnect the fuel pressure regulator valve connector.
3.
Measure resistance between the fuel pressure regulator valve terminals 1 and 2.
4.
Check that the resistance is within the specification.

Specification: Refer to “Specification”


    Canister Close Valve (CCV). Description and Operation
    Description Canister Close Valve (CCV) is installed on the canister ventilation line. It seals evaporative emission control system by shutting the canister from the atmosphere when leakage d ...