Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation - Engine Control System - Engine Control/Fuel SystemHyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation

Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


    Injector. Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...

    Purge Control Solenoid Valve (PCSV). Specifications
    Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...

    See also:

    Manual heating and air conditioning
    The heating and cooling system can be controlled manually by pressing buttons or turning knob(s) other than the AUTO button. In this case, the system works sequentially according to the order of b ...

    Description and Operation
    Description Mobile Telemetics System (MTS) Hyundai motor companies are now faced with the task of shifting their paradigm from vehicle-centered services to customer valuecentered services, ...

    General Information
    General Troubleshooting Information Before Troubleshooting 1. Check applicable fuses in the appropriate fuse/relay box. 2. Check the batter ...