Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


    Injector. Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...

    Purge Control Solenoid Valve (PCSV). Specifications
    Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...

    See also:

    Wheel. Repair procedures
    Hub nut tightening sequence Tighten the hub nuts as follows. Tightening torque: 88.3 ~ 107.9 N.m (9.0 ~ 11.0 kgf.m, 65.1 ~ 79.6 lb-ft) ...

    Side Airbag (SAB) Module. Repair procedures
    Removal The side airbag cannot be disassembled from the seat back assembly, so replace the seat back assembly when replacing ...

    Yaw-rate and Lateral G Sensor. Description and Operation
    Description When the vehicle is turning with respect to a vertical axis the yaw rate sensor detects the yaw rate electroniclly by the vibration change of plate fork inside the yaw rate senso ...