Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM grounds the valve control line. When the passage
is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.
Injector. Repair procedures
Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...Purge Control Solenoid Valve (PCSV). Specifications
Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...See also:
Components and Components Location
Component Location
1. Hood switch
2. Burglar horn
3. BCM and RF antenna
4. Key warning switch
5. Front door switch
6. Front door lock actuator & switch
...
Components and Components Location
Components
1. Steering wheel
2. Steering column
3. ECU
4. Motor
5. Steering gear box
...
Valve Body. Repair procedures
Removal
1.
Remove the battery and the battery tray. (Refer to
"Charging system" in EE group.)
2.
Remove the under cover (A).
...