Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM grounds the valve control line. When the passage
is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.

Injector. Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance betwee ...
Purge Control Solenoid Valve (PCSV). Specifications
Specification
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C(68°F)]
...
See also:
Driver's and passenger's front air bag
Driver’s front air bag
Your vehicle is equipped with a Supplemental Restraint (Air Bag) System and lap/shoulder
belts at both the driver and passenger seating positions. The indications of th ...
Fuel Filler Door Open Switch. Repair procedures
Inspection
1.
Remove the switch assembly (A) from the crash pad lower panel.
2.
Disconnect the switch connector.
3 ...
Specifications
Specifications
Items
Specifications
Rated voltage
DC 12V
Operating temperature range
-30°C ~ +80°C (-22 ~ +176°F)
...