Hyundai Sonata: Specifications - General Information - Emission Control SystemHyundai Sonata: Specifications

Specifications

Purge Control Solenoid Valve (PCSV)
▷ Specification
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C(68°F)]

Fuel Tank Pressure Sensor (FTPS)
▷ Type: Piezo-Resistive Pressure Sensor
▷ Specification
Pressure
[kPa (kgf/cm², in H2O)]
Output Voltage (V)
-6.67 (-0.068, -26.8)
0.5
0
2.5
+6.67 (0.068, 26.8)
4.5

Canister Close Valve (CCV)
▷ Specification
Item
Specification
Coil Resistance (Ω)
19.9 ~ 22.9 [20°C(68°F)]


Tightening Torques

Item
kgf.m
N.m
lb-ft
Positive crankcase ventilation valve installation
0.19 ~ 0.29
1.9 ~ 2.8
1.4 ~ 2.1
Canister installation bolt
0.4 ~ 0.6
3.9 ~ 5.9
2.9 ~ 4.3


    Description and Operation
    Description Emissions Control System consists of three major systems. • The Crankcase Emission Control System prevents blow-by gas from releasing into the atmosphere. T ...

    Troubleshooting
    Troubleshooting Symptom Suspect area Engine will not start or struggle to start Vapor hose damaged or disconnected Engine strugg ...

    See also:

    Canister Close Valve (CCV). Description and Operation
    Description Canister Close Valve (CCV) is installed on the canister ventilation line. It seals evaporative emission control system by shutting the canister from the atmosphere when leakage d ...

    Fan speed control
    The ignition switch must be in the ON position for fan operation. The fan speed control knob allows you to control the fan speed of the air flowing from the ventilation system. To change the fa ...

    Manifold Absolute Pressure Sensor (MAPS). Description and Operation
    Description Manifold Absolute Pressure Sensor (MAPS) is a speed-density type sensor and is installed on the surge tank. It senses absolute pressure of the surge tank and transfers the analog ...