Inspection
1. |
Turn the ignition switch OFF.
|
2. |
Disconnect the VIS valve connector.
|
3. |
Measure resistance between VIS valve terminals 1 and 2.
Specification:
Refer to "Specification"
|
|
Removal
1. |
Turn the ignition switch OFF and disconnect the battery negative
(-) cable.
|
2. |
Disconnect the variable intake solenoid valve connector (A).
|
3. |
Disconnect the vacuum hoses (B,C) from the valve.
|
4. |
Remove the installation bolt (D), and then remove the valve from
the surge tank.

|
Installation
•
|
Install the component with the specified torques.
|
•
|
Note that internal damage may occur when the component
is dropped. If the component has been dropped, inspect before
installing.
|
|
•
|
Use care to keep foreign material out of the valve.
|
|
1. |
Installation is reverse of removal.
|
Description
Fuel Pressure Regulator Valve is installed on the high pressure fuel pump
and controls fuel flow flowing into the injectors in accordance with the ECM
signal calculated based on ...
See also:
Torque Converter Control Solenoid Valve (T/CON_VFS). Repair procedures
Inspection
1.
Turn ignition switch OFF.
2.
Disconnect the oil temperature sensor connector.
3.
Measure ...
Opening the hood
WARNING
Open the hood after turning off the engine on a flat surface, shifting the
shift lever to the P(Park) position for automatic transaxle and to the 1st(First)
gear or R(Reverse) for man ...
Curtain air bag
Curtain air bags are located along both sides of the roof rails above the front
and rear doors.
They are designed to help protect the heads of the front seat occupants and the
rear outboa ...