Purge Control Solenoid Valve (PCSV)
▷ Specification
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C(68°F)]

Fuel Tank Pressure Sensor (FTPS)
▷ Type: Piezo-Resistive Pressure Sensor
▷ Specification
Pressure
[kPa (kgf/cm², in H2O)]
Output Voltage (V)
-6.67 (-0.068, -26.8)
0.5
0
2.5
+6.67 (0.068, 26.8)
4.5

Canister Close Valve (CCV)
▷ Specification
Item
Specification
Coil Resistance (Ω)
19.9 ~ 22.9 [20°C(68°F)]


Tightening Torques

Item
kgf.m
N.m
lb-ft
Positive crankcase ventilation valve installation
0.19 ~ 0.29
1.9 ~ 2.8
1.4 ~ 2.1
Canister installation bolt
0.4 ~ 0.6
3.9 ~ 5.9
2.9 ~ 4.3


    Description and Operation
    Description Emissions Control System consists of three major systems. • The Crankcase Emission Control System prevents blow-by gas from releasing into the atmosphere. T ...

    Troubleshooting
    Troubleshooting Symptom Suspect area Engine will not start or struggle to start Vapor hose damaged or disconnected Engine strugg ...

    See also:

    Engine start/stop button position
    OFF To turn off the engine, press the engine start/stop button with the engine start/stop button in the ON position and the shift lever in P(Park). When you press the engine start/stop button wit ...

    Heated Oxygen Sensor (HO2S). Description and Operation
    Description Heated Oxygen Sensor (HO2S) consists of zirconium and alumina and is installed both upstream and downstream of the Manifold Catalytic Converter. The sensor output voltage varies ...

    Antenna
    Glass antenna When the radio power switch is turned on while the engine start/stop button is in either the “ON” or “ACC” position, your car will receive both AM and FM broadcast signa ...