Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation - Engine Control System - Engine Control/Fuel System - Hyundai Sonata YF 2011-2019 Service ManualHyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation

Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


    Injector. Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...

    Purge Control Solenoid Valve (PCSV). Specifications
    Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20∞C(68∞F)] ...

    See also:

    Mirror. Repair procedures
    Replacement Outside Rear View Mirror Replacement Х When prying with a flat-tip screwdriver, wrap ...

    CVVT Oil Control Valve (OCV). Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the OCV connector. 3. Measure resistance between the ...

    Components and Components Location
    Components 1. Telemetics Unit (TMU) 2. AVN or Audio Head Unit 3. Room Mirror Switch (Blue Link button, Center button, SOS button) 4. Mic 5. Roof Antenna (GPS+CD ...