Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation - Engine Control System - Engine Control/Fuel SystemHyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation

Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


    Injector. Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...

    Purge Control Solenoid Valve (PCSV). Specifications
    Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...

    See also:

    Antenna Coil. Repair procedures
    Replacement 1. Disconnect the negative (-) battery terminal. 2. Remove the steering column upper and lower shrouds after loosening the scr ...

    Phone setup
    Press the key Select [Phone] through TUNE knob or key Select menu through TUNE knob Pair Phone CAUTION To pair a Bluetooth® Wireless Technology enabled mobile phone, authentication and ...

    Description and Operation
    Description Burglar Alarm System The burglar alarm system is armed automatically after the doors, hood, and trunk lid are closed and locked. The system is set off when any of these ...