Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation - Engine Control System - Engine Control/Fuel SystemHyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation

Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


    Injector. Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...

    Purge Control Solenoid Valve (PCSV). Specifications
    Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...

    See also:

    Airbag Module Disposal. Description and Operation
    Airbag Disposal Special tool required Deployment tool 0957A-34100A Before scrapping any airbags or side airbags (including those installed in vehicle to be scrapped), the airb ...

    Description and Operation
    Function Of Safety Power Window When driver door power window auto-up switch is operated, safety function is activated. 1. Safety function condition When detect ...

    Fan speed control
    The fan speed can be set to the desired speed by pushing the fan speed control button. To change the fan speed, press the right of the button () for higher speed, or press the left of the butto ...