Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM grounds the valve control line. When the passage
is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.
Injector. Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance betwee ...
Purge Control Solenoid Valve (PCSV). Specifications
Specification
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C(68°F)]
...
See also:
Description and Operation
Cruise Control
The cruise control system is engaged by the cruise "ON/OFF" main switch
located on right of steering wheel column. The system has the capability to
cruise, coast, ac ...
Troubleshooting
Basic Troubleshooting
Basic Troubleshooting Guide
Customer Problem Analysis Sheet
Basic Inspection Procedure
Measuring Condition of Electronic Parts' Resistance
The mea ...
Relay Box (Passenger Compartment). Repair procedures
Fuse Inspection
1.
Be sure there is no play in the fuse holders, and that the fuses
are held securely.
2.