Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation
Description
Purge Control Solenoid Valve (PCSV) is installed on the surge tank and
controls the passage between the canister and the intake manifold. It is a solenoid
valve and is open when the ECM grounds the valve control line. When the passage
is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake
manifold.

Injector. Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the injector connector.
3.
Measure resistance betwee ...
Purge Control Solenoid Valve (PCSV). Specifications
Specification
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C(68°F)]
...
See also:
Driving your vehicle
WARNING - ENGINE EXHAUST CAN BE DANGEROUS!
Engine exhaust fumes can be extremely dangerous. If, at any time, you smell
exhaust fumes inside the vehicle, open the windows immediately.
Do not inh ...
Repair procedures
Removal
1.
Disconnect the negative (-) battery terminal.
2.
Remove the driver crash pad lower panel.
(Refer to the BD group - "Cra ...
Alignment. Repair procedures
Front Wheel Alignment
When using a commercially available computerized wheel alignment