Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation - Engine Control System - Engine Control/Fuel SystemHyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation

Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


    Injector. Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...

    Purge Control Solenoid Valve (PCSV). Specifications
    Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...

    See also:

    Air intake control
    This is used to select outside (fresh) air position or recirculated air position. To change the air intake control position, push the control button. Recirculated air position The indicator ...

    Balance Shaft & Oil Pump. Components and Components Location
    Components 1. Balance shaft & oil pump assembly 2. Balance shaft chain tensioner 3. Balance shaft chain 4. Balance shaft chain sprocket 5. Balance shaft cha ...

    Shift Lever. Repair procedures
    Removal 1. Remove the center console assembly. (Refer to "Interior" in BD group.) 2. Remove the control cable (A). ...