Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation - Engine Control System - Engine Control/Fuel SystemHyundai Sonata: Purge Control Solenoid Valve (PCSV). Description and Operation

Description

Purge Control Solenoid Valve (PCSV) is installed on the surge tank and controls the passage between the canister and the intake manifold. It is a solenoid valve and is open when the ECM grounds the valve control line. When the passage is open (PCSV ON), fuel vapor stored in the canister is transferred to the intake manifold.


    Injector. Repair procedures
    Inspection 1. Turn the ignition switch OFF. 2. Disconnect the injector connector. 3. Measure resistance betwee ...

    Purge Control Solenoid Valve (PCSV). Specifications
    Specification Item Specification Coil Resistance (Ω) 19.0 ~ 22.0 [20°C(68°F)] ...

    See also:

    Parts
    When replacing parts, use HYUNDAI genuine parts. Replacement Standard values, such as torques and certain adjustments, must be strictly observed in the reassembly of all parts. If removed, the ...

    Description and Operation
    Cruise Control The cruise control system is engaged by the cruise "ON/OFF" main switch located on right of steering wheel column. The system has the capability to cruise, coast, ac ...

    Cylinder Head Components and Components Location
    Components 1. Cylinder head assembly2. MLA3. Retainer lock4. Retainer 5. Valve stem seal6. Valve spring7. Valve spring seat8. OCV (Oil Control Valve)9. Exhaust valve10. Intake valve11. Cylinder h ...