Hyundai Sonata: Purge Control Solenoid Valve (PCSV). Schematic Diagrams
Circuit Diagram

Purge Control Solenoid Valve (PCSV). Specifications
Specification
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C(68°F)]
...
Purge Control Solenoid Valve (PCSV). Repair procedures
Inspection
1.
Turn the ignition switch OFF.
2.
Disconnect the PCSV connector.
3.
Measure resistance between th ...
See also:
Weight Classification System (WCS). Description and Operation
Description
In contrast to the initial one-stage airbag systems, newer restraint systems
involve complex logic to select, or alternatively suppress, various levels of
safety system deploymen ...
Changing tires
1. Park on a level surface and apply the parking brake firmly.
2. Shift the shift lever into R (Reverse) with manual transaxle or P (Park) with
automatic transaxle.
3. Activate the hazard warn ...
Specifications
Specifications
Purge Control Solenoid Valve (PCSV)
▷ Specification
Item
Specification
Coil Resistance (Ω)
19.0 ~ 22.0 [20°C( ...