Hyundai Sonata: Solenoid valve. Specifications - Valve Body System - Automatic Transaxle SystemHyundai Sonata: Solenoid valve. Specifications

Specification

Item
Function
Piece
Specification
VFS
 
 
26/B
T/Con
2
Control pressure: 9.81~500.14kpa (0.1~5.1kgf/cm², 1.42~72.54 psi)
Current value: 50~850mA
Low Type, 5.1Ω
Line pressure
control
1
Control pressure: 500.14~9.81kpa (5.1~0.1kgf/cm², 72.54~1.42psi)
Current value: 50~850mA
High Type, 5.1Ω
35R
UD
OD
3
Control pressure: 500.14~9.81kpa (5.1~0.1kgf/cm², 72.54~1.42psi)
Current value: 50~850mA
High Type, 5.1Ω
On/Off
SS-A
SS-B
2
Control pressure: 490.33kpa (5.0kgf/cm², 71.12psi)
10~11Ω
Low Type

Solenoid Valve Operation Table
 
SS-A
SS-B
UD-VFS
OD-VFS
35R-VFS
26-VFS
N/H
N/H
N/H
N/L
N, P
●
 
●
 
●
 
1
Δ
 
 
Δ
●
 
2
 
 
 
●
●
●
3
 
●
 
●
 
 
4
 
 
 
 
●
 
5
 
●
●
 
 
 
6
 
 
●
 
●
●
L
●
 
 
 
●
 
R
●
●
●

 
 


    Valve Body. Repair procedures
    Removal 1. Remove the battery and the battery tray. (Refer to "Charging system" in EE group.) 2. Remove the under cover (A). ...

    Solenoid valve. Repair procedures
    Removal 1. Remove the battery and the battery tray. (Refer to "Charging system" in EE group.) 2. Remove the under cover (A). ...

    See also:

    Owner’s responsibility
    ✽ NOTICE Maintenance Service and Record Retention are the owner's responsibility. You should retain documents that show proper maintenance has been performed on your vehicle in accordan ...

    Rail Pressure Sensor (RPS). Description and Operation
    Description Rail Pressure Sensor (RPS) is installed on the delivery pipe and measures the instantaneous fuel pressure in the delivery pipe. The sensing element (Semiconductor element) built ...

    Fan speed control
    The fan speed can be set to the desired speed by pushing the fan speed control button. To change the fan speed, press the right of the button () for higher speed, or press the left of the butto ...